BSC-CB1-0500K1075K, 20-ft high-cube container c&i ess, lit on a dark floor
BSC-CB1-0500K1075KProduct image, AI-lit from manufacturer photograph, not an installationSpecifications are confirmed from documents, never read from this image.

BESS & Microgrids

20-ft high-cube container C&I ESS

BSC-CB1-0500K1075K

Containerized air-cooled commercial and industrial storage, published by Bescore as the 20HC ESS, model BSC-CB10500K1075K-GS, on its 2024 sheet.

It does not appear in Bescore's current product range, so Metro Power confirms availability with Bescore before an offer.

Manufacturer photograph

Inspect the product itself.

The image above is AI-lit from this manufacturer photograph for presentation, and no specification is read from it. Use the six views to inspect the manufacturer image, its close view, interfaces, system context, drawing gate and evidence boundary.

BSC-CB1-0500K1075K, Studio view

PRODUCT IMAGE · 01/06BSC-CB1-0500K1075KProduct image from the available source. Confirm the exact model, ratings, dimensions and interfaces by document.

IMAGE REFERENCEManufacturer renderRatings, dimensions, interfaces and compliance are confirmed from the applicable documents.

POSSIBLE USECommercial, industrial and microgrid energy storageA starting point for discussion, not an automatic recommendation.
WHAT WE CAN CONFIRM TODAYAvailability needs checkingThis may suit the need, but Metro Power must reconfirm the current model, configuration and availability.
FIRST PROJECT CHECK12 months of bills and tariffIf you do not know this yet, Metro Power can help identify what is needed.
Published specifications

20-ft high-cube container C&I ESS, as published.

Figures as Bescore publishes them.

BSC-CB1-0500K1075K published specifications
ModelBSC-CB1-0500K1075K
Type20-ft high-cube container C&I ESS
System familyBESS & Microgrids
Power and energy
  • 500 kW rated power
  • 1,075 kWh rated energy
AC connection380/400 V AC, 50/60 Hz
DC voltage600 to 900 V DC battery range
TransformerOptional isolation transformer and static transfer switch (STS)
Ingress and environmentIP55

Evidence level: availability needs checking. Confirm the exact model code, option, revision and controlling terms of reference (TOR) before using any fact in a compliance statement, offer or installation decision.

What the storage system connects to.

A battery only earns its place through the equipment around it: the supply it charges from, the switchgear that isolates it, the loads it protects and the sources a controller must coordinate.

Illustrative evening scene of containerized battery storage beside switchgear and a transformer
Illustrative scene, not a Metro Power site or installation.

Power path

  1. Utility gridAbsent on an off-grid site.
  2. TransformerService transformer, or an isolation transformer for an island.
  3. Switchgear and transfer deviceIsolates the system and moves the site between grid and island.
  4. This productBSC-CB1-0500K1075KStores energy as DC and delivers it through the PCS.
  5. Site loadsCritical loads first when the battery is the only source.

Other sources the controller coordinates

  1. SolarCharges the battery or serves load directly.
  2. Diesel generatorBackup, or the second source on an island.
  3. From the BSC-CB1-0500K1075KDispatch rules decide which source serves which load.
PowerReal product photographDrawn: equipment Metro Power does not supply
Options and differences

From pack to power station, as the principal publishes them

Storage is built in steps. Each step adds energy, voltage and the equipment needed to connect it.

  • Battery pack

    14 kWh at 51.2 V DC. The building block.

  • Battery rack

    215 kWh at 768 V DC. Packs in series, fitted inside an enclosure.

  • Cabinet system

    105 kW with 215 kWh. Battery, PCS and controls in one outdoor cabinet.

  • Battery compartment

    Up to 5,016 kWh at 1,331.2 V DC. DC only; converts in a separate station.

  • PCS and MV station

    Up to 5,000 kW, stepped up to 10, 20 or 35 kV.

Application context

Where this product fits.

Typical applications for this product family. Fit still depends on the exact service, duty, operating objective and approved configuration, so treat these as starting points rather than recommendations.

  1. 01Peak shaving
  2. 02Solar self-consumption
  3. 03Critical-load backup
  4. 04Diesel optimization
  5. 05Renewable smoothing
  6. 06Grid-tied storage on a constrained feeder

Before an offer

What Metro Power confirms before BSC-CB1-0500K1075K is offered.

Three steps, in the order they happen: what the public record already shows, what your project must confirm, and the controlled documents that close the loop.

01Professional documentation

One product identity. Five controlled evidence gates.

This schedule shows what the public record supports and what Metro Power must still match before the product becomes a technical or commercial commitment.

ControlCurrent public recordProject release requirementStatus
IdentityBSC-CB1-0500K1075K · 20-ft high-cube container C&I ESSExact model code, production revision and option scheduleAvailability needs checking
ApplicationContainerized air-cooled commercial and industrial storage, published by Bescore as the 20HC ESS, model BSC-CB10500K1075K-GS, on its 2024 sheet. It does not appear in Bescore's current product range, so Metro Power confirms availability with Bescore before an offer.Approved service, duty, site and operating useApplication review
Technical facts500 kW rated power · 1,075 kWh rated energy · 380/400 V AC, 50/60 Hz; 600 to 900 V DC battery range · Optional isolation transformer and static transfer switch (STS); IP55Controlled datasheet and requirement-by-requirement compliance matrixConfiguration check
Information to prepare12 months of bills and tariff · Interval load data · Critical loads and outage history · Solar/generator details · Single-line and transformer data · Site, fire and interconnection constraints · Service voltage and frequency (the Philippine grid is 60 Hz) · Existing solar: inverter make, rating and how it connects · The largest motor that must start in an island, with its starting current · Distance to the coast and exposure to salt airDrawings, terminals, communications, accessories and system interfacesEvidence required
Approval and supplyNot shown on this pageCurrent certificates, test records, principal confirmation, availability and deliveryRelease before offer

02Configuration gate

What must be confirmed before an offer.

Capacity, savings and backup duration require validated interval load, site and operating data; monthly consumption alone is insufficient. Frequency, service voltage and the largest motor to be started are confirmed before any model is proposed.

  1. 0112 months of bills and tariff
  2. 02Interval load data
  3. 03Critical loads and outage history
  4. 04Solar/generator details
  5. 05Single-line and transformer data
  6. 06Site, fire and interconnection constraints

03Controlled document request

Request a controlled offer.

Need the current datasheet or compliance evidence? Metro Power will match the document revision, model and configuration to your requirement before release. Tell us the decision, TOR or application the document must support.